When choosing your bathing therapy type and/or any system upgrades, it is important to double check the electrical requirements needed to support such choices. Below are the recommended electrical specifications.
Electrical Requirements
| Option | Volts | Amps | Circuit Requirements |
|---|---|---|---|
| Whirlpool | 115 | 13 | One 20amp dedicated GFCI protected |
| Thermal Air | 115 | 8 | One 15amp dedicated GFCI protected |
| *Combo System | 115 | 13 pump / 8 blower | One 20amp and One 15 amp dedicated GFCI protected |
| Hydro Indulge | 115 | 8 | One 15 amp dedicated GFCI protected |
| Inline Heater 1500 | 115 | 12.5 | One 15 amp dedicated GFCI protected |
| **Inline Heater 600W | 115 | 6 | One 15 amp dedicated GFCI protected |
| Fusion 1500W | 115 | 12.5 | One 15 amp dedicated GFCI protected |
| Fusion 600W | 115 | 6 | One 15 amp dedicated GFCI protected |
“Options” refer to features that are added to a standard product and will result in additional costs
*The Combo System bath therapy type includes both Thermal Air and Whirlpool Systems
** The Inline Heater 600W can share the circuit on a Studio Collection Whirlpool pump and does not require a dedicated circuit